Phone: 519-737-7333 | Fax: 519-737-7337|info@bluewaterheater.com

WATLOW AIR & GAS IN-LINE CIRCULATION HEATERS

These Heaters are all rated at 23 watt/Sq. In. for Air & Gas Heating

Please consult Bluewater Heater for gas flow rates and pressure drops.

Watlow circulation heaters combine the popular Watlow WATROD® or FIREBAR® heating elements together with a tank, insulation, terminal enclosure, mounting brackets, inlet, and outlet connections to form a complete assembly. Watlow circulation heaters, therefore, provide a ready-made means to install electric heating with a minimal amount of time and labor.

Category:

Description

Other Circulation Heaters Available from WATLOW – Please Inquire

 

Material Maximum Operating Temperatures Maximum Watt Densities
°F °C W/in2 W/cm2
Incoloy® 1600 870 120 18.6
Stainless steel 1200 650 120 18.6
Steel 750 400 120 18.6
Copper 350 175 120 18.6
  • Watt densities to 120 W/in2 (18.6 W/cm2)
  • Wattages to three megawatts
  • UL® and CSA component recognition to 600VAC
  • Ratings to ANSI Class 600 pressure class
  • Incoloy® sheath temperatures to 1600°F (870°C)
  • Passivated 316 stainless steel sheath temperatures to 1200°F (650°C)
  • Steel sheath temperatures to 750°F (400°C)
  • Copper sheath temperatures to 350°F (175°C)

These Heaters are all rated at 23 watt/Sq. In. for Air & Gas Heating

Please consult Bluewater Heater for gas flow rates and pressure drops.

Watlow circulation heaters combine the popular Watlow WATROD® or FIREBAR® heating elements together with a tank, insulation, terminal enclosure, mounting brackets, inlet, and outlet connections to form a complete assembly. Watlow circulation heaters, therefore, provide a ready-made means to install electric heating with a minimal amount of time and labor.

Watlow circulation heaters are designed to force circulated air and gases over a heating element. Watlow circulation heaters are ideal for either in-line or side-arm operations. By using industry-leading FIREBAR® or WATROD® heating elements, these Watlow circulation heaters deliver fast response and even heat distribution.

Watlow circulation heaters maintain the high performance capabilities for which all Watlow heaters are known. Watlow circulation heaters are rated up to one megawatt, generating watt densities up to 23 watt/sq. In. for Air & Gas and sheath temperatures of up to 1600°F (depending upon sheath material). The tanks are insulated with one inch of thermal insulation rated to 750°F to reduce heat loss. A heavy gauge steel jacket protects the entire assembly. A wide range of sheath materials, wattages, vessel sizes and materials, pressure ratings, terminal enclosures and controls are available to the Watlow circulation heaters to meet virtually all your circulation heater assembly needs.

Circulation heaters provide a ready-made means to install electric heating with a minimal amount of time and labor. This is accomplished by combining heating elements, vessel, insulation, terminal enclosure, mounting brackets and inlet and outlet connections into a complete assem

Watlow® meets virtually all your circulation heater assembly needs with made-to-order units. These units can be made from a wide range of heating element sheath materials, wattages, vessel sizes and materials, pressure ratings, terminal enclosures and controls.

 

 

Features Benefits
Catalog screw plug and flange part numbers
  • Provides a wide selection of WATROD and FIREBAR elements to meet specific application requirements
ANSI B16.5 Class 150 on 4 or 6 inch FIREBAR element flanges and 3 to 14 inch WATROD element flanges
  • Meets recognized agency standards
FIREBAR assemblies pack more wattage in a smaller heater bundle
  • Replaces larger flanges with round tubular elements, with a smaller package
Compacted MgO insulation filled elements
  • Maximizes dielectric strength, heat transfer and life
1 inch (25 mm) thermal insulation rated to 750°F (400°C)
  • Reduces heat loss from the vessel
Heavy-guage steel jacket (shroud)
  • Protects thermal insulation and heating vessel and comes with protective primer coating
All catalog units rated to ANSI pressure Class 150
  • Provides pressure vessels (tanks) that are either carbon or 316 stainless steel
Standard offering includes units rated for up to and including ANSI pressure class 600 (application review required)
  • Provides pressure vessels (tanks) available in carbon steel, 304 or 316 stainless steel materials
  • Includes schedule 40, standard and 80 pipe used in the pressure vessel construction